Empresa
¿Quiénes somos? Visión y Valores
Herramientas
Email Checker Vigía DNS SSL Checker Password Strength HTTP Headers
Alertas
Todas las alertas Vulnerabilidades Incidentes Solo críticas En CISA KEV
Editorial
Análisis técnico ¿Cuál es mi IP?
Blog
Blog 2MCI ISO 27001 Amenazas LATAM Recursos Gratuitos eBook Gratuito Newsletter Podcast / YouTube
Empresa
Servicios Contacto Suscribirse al Newsletter
Nuevo en 2MCI
Crear cuenta gratis Ver herramientas sin registro
Ya tengo cuenta
Iniciar sesión
Equipo
Portal interno 2MCI
Alto CVE-2026-100709 Multiple Vendors

[CVE-2026-100709] Froxlor through 2.3.10 stores only a numeric user ID in remembered-2FA tokens (panel_2fa_tokens) wit…

Vulnerabilidad · Publicado 26/09/2026

7.5
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

Froxlor through 2.3.10 stores only a numeric user ID in remembered-2FA tokens (panel_2fa_tokens) without recording the account namespace, and the remembered-token lookup during login is not constrained to the customer or administrator account type. Because customer and administrator IDs are allocated from separate namespaces, a remembered-2FA token legitimately issued to a customer with a given ID…

Descripción técnica

Descripción técnica

Froxlor through 2.3.10 stores only a numeric user ID in remembered-2FA tokens (panel_2fa_tokens) without recording the account namespace, and the remembered-token lookup during login is not constrained to the customer or administrator account type. Because customer and administrator IDs are allocated from separate namespaces, a remembered-2FA token legitimately issued to a customer with a given ID also matches an administrator with the same ID. An attacker who controls a customer account with a colliding ID, holds a valid remembered-2FA cookie for it, and already knows the target administrator's password can bypass the administrator's TOTP second factor and obtain an authenticated administrator session. This is a second-factor bypass only; it does not defeat password authentication. Fixed in 2.3.12.

Puntuación CVSS

Score: 7.5/10 — Severidad: HIGH — Estado NIST: Deferred

CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Debilidades (CWE)

CWE-287

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.