Empresa
¿Quiénes somos? Visión y Valores
Herramientas
Email Checker Vigía DNS SSL Checker Password Strength HTTP Headers Password Generator VPN PSK Generator
Alertas
Todas las alertas Vulnerabilidades Incidentes Solo críticas En CISA KEV Vigía LATAM
Editorial
Análisis técnico ¿Cuál es mi IP?
Blog
Blog 2MCI Noticias ISO 27001 Amenazas LATAM Recursos Gratuitos eBook Gratuito Newsletter Podcast / YouTube
Empresa
Servicios Contacto Suscribirse al Newsletter
Nuevo en 2MCI
Crear cuenta gratis Ver herramientas sin registro
Ya tengo cuenta
Iniciar sesión
Equipo
Portal interno 2MCI
Alto CVE-2026-134034 Multiple Vendors

[CVE-2026-134034] HortusFox is a self-hosted web application for collaborative plant management. Prior to 6.2, the tog…

Vulnerabilidad · Publicado 24/11/2026

8.1
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

HortusFox is a self-hosted web application for collaborative plant management. Prior to 6.2, the toggle_boolean_value() handler in app/controller/admin.php passes the name parameter of the /admin/environment/boolean/toggle route in app/config/routes.php to AppModel::updateSingle() in app/models/AppModel.php, which concatenates the parameter into the SQL UPDATE identifier position without validatio…

Descripción técnica

Descripción técnica

HortusFox is a self-hosted web application for collaborative plant management. Prior to 6.2, the toggle_boolean_value() handler in app/controller/admin.php passes the name parameter of the /admin/environment/boolean/toggle route in app/config/routes.php to AppModel::updateSingle() in app/models/AppModel.php, which concatenates the parameter into the SQL UPDATE identifier position without validation. An unauthenticated attacker can induce a signed-in administrator to open a crafted link, causing SQL injection that permits expressions and subqueries to read database contents, including an administrator password hash, or modify settings to enable passwordless administrator access. The hash alone does not permit direct login. This issue is fixed in version 6.2.

Puntuación CVSS

Score: 8.1/10 — Severidad: HIGH — Estado NIST: Deferred

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N

Debilidades (CWE)

CWE-89, CWE-352

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.