Alto CVE-2026-19570 Multiple Vendors

[CVE-2026-19570] The LE Audio Broadcast Sink in subsys/bluetooth/audio/bap_broadcast_sink.c copies subgroup metadata …

Vulnerabilidad · Publicado 09/10/2026

8.8
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

The LE Audio Broadcast Sink in subsys/bluetooth/audio/bap_broadcast_sink.c copies subgroup metadata from a received Basic Audio Announcement (BASE) into the static Broadcast Audio Scan Service parameter structure mod_src_param without any bounds check. In base_subgroup_meta_cb() the destination element was selected as mod_src_param.subgroups[mod_src_param.num_subgroups] with no test against ARRAY_…

Descripción técnica

Descripción técnica

The LE Audio Broadcast Sink in subsys/bluetooth/audio/bap_broadcast_sink.c copies subgroup metadata from a received Basic Audio Announcement (BASE) into the static Broadcast Audio Scan Service parameter structure mod_src_param without any bounds check. In base_subgroup_meta_cb() the destination element was selected as mod_src_param.subgroups[mod_src_param.num_subgroups] with no test against ARRAY_SIZE(mod_src_param.subgroups) (sized by CONFIG_BT_BAP_BASS_MAX_SUBGROUPS, default 1), and the metadata was copied with memcpy() using the raw on-air length returned by bt_bap_base_get_subgroup_codec_meta() into a metadata array sized by CONFIG_BT_AUDIO_CODEC_CFG_MAX_METADATA_SIZE (default 4). The BASE validator bt_bap_base_get_base_from_ad() only checks structural consistency and permits up to ~24 subgroups and metadata LTVs of ~240 octets. The defect is reached from the periodic advertising receive callback: pa_recv() → bt_data_parse() → pa_decode_base() → update_recv_state_base() → bt_bap_base_foreach_subgroup() → base_subgroup_meta_cb(). Every broadcast sink registers a scan-delegator receive state at creation (bt_bap_broadcast_sink_create() calls broadcast_sink_add_src()), and CONFIG_BT_BAP_BROADCAST_SINK depends on CONFIG_BT_BAP_SCAN_DELEGATOR, so the path is active in every broadcast-sink build once the device is periodic-advertising-synced. An attacker in radio range who operates a broadcast source the device syncs to — or who impersonates the advertiser address and SID of one already in use, periodic advertising data being unauthenticated — can change the BASE at will; each new BASE is re-parsed. A crafted BASE therefore writes attacker-chosen bytes past the end of a fixed static object in .bss: up to roughly 236 bytes for an oversized metadata LTV, plus whole struct bt_bap_bass_subgroup records for each subgroup beyond CONFIG_BT_BAP_BASS_MAX_SUBGROUPS. This is memory corruption of adjacent Bluetooth-audio state reachable with no pairing, bonding or GATT connection, with a potential for remote code execution in the Bluetooth RX thread; in addition, the unvalidated metadata_len is forwarded to bt_bap_scan_delegator_mod_src(), which neither clamps it nor rejects it, leading to a further copy into the receive state and to out-of-bounds memory being disclosed in the BASS receive-state notification sent to a connected Broadcast Assistant. The fix rejects a BASE carrying more subgroups than the receive state can hold (discarding the update entirely) and omits metadata that does not fit rather than copying it, and additionally honours the previously-ignored error return of the subgroup decode pass.

Puntuación CVSS

Score: 8.8/10 — Severidad: HIGH — Estado NIST: Received

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Debilidades (CWE)

CWE-120, CWE-787

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados