Empresa
¿Quiénes somos? Visión y Valores
Herramientas
Email Checker Vigía DNS SSL Checker Password Strength HTTP Headers
Alertas
Todas las alertas Vulnerabilidades Incidentes Solo críticas En CISA KEV
Editorial
Análisis técnico ¿Cuál es mi IP?
Blog
Blog 2MCI ISO 27001 Amenazas LATAM Recursos Gratuitos eBook Gratuito Newsletter Podcast / YouTube
Empresa
Servicios Contacto Suscribirse al Newsletter
Nuevo en 2MCI
Crear cuenta gratis Ver herramientas sin registro
Ya tengo cuenta
Iniciar sesión
Equipo
Portal interno 2MCI
Alto CVE-2026-42805 Multiple Vendors

[CVE-2026-42805] A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C librar…

Vulnerabilidad · Publicado 10/09/2026

8.4
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c).

The function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping th…

Descripción técnica

Descripción técnica

A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c). The function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping the value. When copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary. This memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption.

Puntuación CVSS

Score: 8.4/10 — Severidad: HIGH — Estado NIST: Received

CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Debilidades (CWE)

CWE-121

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.