Crítico CVE-2026-64016 Multiple Vendors

[CVE-2026-64016] In the Linux kernel, the following vulnerability has been resolved: ksmbd: fix durable reconnect er…

Vulnerabilidad · Publicado 19/07/2026 · Actualizado 01/08/2026

9.8
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Crítico
Resumen ejecutivo

In the Linux kernel, the following vulnerability has been resolved:

ksmbd: fix durable reconnect error path file lifetime

After a durable reconnect succeeds, ksmbd_reopen_durable_fd() republishes
the same ksmbd_file into the session volatile-id table. If smb2_open()
then takes a later error path, cleanup first calls ksmbd_fd_put(work, fp)
and then unconditionally calls ksmbd_put_durable_fd(dh_in…

Descripción técnica

Descripción técnica

In the Linux kernel, the following vulnerability has been resolved: ksmbd: fix durable reconnect error path file lifetime After a durable reconnect succeeds, ksmbd_reopen_durable_fd() republishes the same ksmbd_file into the session volatile-id table. If smb2_open() then takes a later error path, cleanup first calls ksmbd_fd_put(work, fp) and then unconditionally calls ksmbd_put_durable_fd(dh_info.fp). In this case fp and dh_info.fp are the same object. The first put drops the reconnect lookup reference, but the final durable put can run __ksmbd_close_fd(NULL, fp). Because the final close is not session-aware, it can free the file object without removing the volatile-id entry that was just published into the session table. Use the session-aware put for the final reconnect drop when the reconnect had already succeeded and the error path is cleaning up the republished file. Earlier reconnect failures, before fp is assigned to dh_info.fp, keep using the durable-only put path.

Puntuación CVSS

Score: 9.8/10 — Severidad: CRITICAL — Estado NIST: Awaiting Analysis

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.
← Volver a todas las alertas