Alto CVE-2026-68581 Multiple Vendors

[CVE-2026-68581] Vikunja versions 0.22.0 through 2.3.0 fail to validate the principal type in API token management. B…

Vulnerabilidad · Publicado 02/08/2026

8.1
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

Vikunja versions 0.22.0 through 2.3.0 fail to validate the principal type in API token management. Because user IDs and link-share IDs are independent numeric sequences and both resolve through a generic web.Auth.GetID() interface, a link-share JWT whose numeric ID equals a target user's ID is treated as that user by the /api/v1/tokens endpoints. An authenticated attacker can obtain a target's num…

Descripción técnica

Descripción técnica

Vikunja versions 0.22.0 through 2.3.0 fail to validate the principal type in API token management. Because user IDs and link-share IDs are independent numeric sequences and both resolve through a generic web.Auth.GetID() interface, a link-share JWT whose numeric ID equals a target user's ID is treated as that user by the /api/v1/tokens endpoints. An authenticated attacker can obtain a target's numeric user ID via authenticated user search, then create link shares on an attacker-writable project until the link-share sequence reaches that value, and use the resulting link-share JWT to list, create, and delete the target user's API tokens (including issuing a new token with attacker-chosen scopes under the target's permissions). Fixed in version 2.4.0.

Puntuación CVSS

Score: 8.1/10 — Severidad: HIGH — Estado NIST: Received

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Debilidades (CWE)

CWE-863

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados