Empresa
¿Quiénes somos? Visión y Valores
Herramientas
Email Checker Vigía DNS SSL Checker Password Strength HTTP Headers
Alertas
Todas las alertas Vulnerabilidades Incidentes Solo críticas En CISA KEV
Editorial
Análisis técnico ¿Cuál es mi IP?
Blog
Blog 2MCI ISO 27001 Amenazas LATAM Recursos Gratuitos eBook Gratuito Newsletter Podcast / YouTube
Empresa
Servicios Contacto Suscribirse al Newsletter
🆕 Nuevo en 2MCI
✨ Crear cuenta gratis 🛠️ Ver herramientas sin registro
Ya tengo cuenta
🔒 Iniciar sesión
Equipo
🏠 Portal interno 2MCI
Alto CVE-2026-7830 Uvnc

[CVE-2026-7830] UltraVNC through 1.8.2.2 uses inadequate cryptography in the MS-Logon II authentication scheme (rfbU…

Vulnerabilidad · Publicado 01/07/2026 · Actualizado 01/08/2026

7.4
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

UltraVNC through 1.8.2.2 uses inadequate cryptography in the MS-Logon II authentication scheme (rfbUltraVNC_MsLogonIIAuth). In rfb/dh.cpp the Diffie-Hellman key exchange is performed with parameters that fit in an unsigned 64-bit integer (DH_MAX_BITS controls the prime size). A 64-bit DH key can be broken by Pollard's rho algorithm in under one second on current hardware. Additionally, the private…

Descripción técnica

Descripción técnica

UltraVNC through 1.8.2.2 uses inadequate cryptography in the MS-Logon II authentication scheme (rfbUltraVNC_MsLogonIIAuth). In rfb/dh.cpp the Diffie-Hellman key exchange is performed with parameters that fit in an unsigned 64-bit integer (DH_MAX_BITS controls the prime size). A 64-bit DH key can be broken by Pollard's rho algorithm in under one second on current hardware. Additionally, the private exponent is generated by the rng() function, which multiplies three libc rand() values seeded from time(NULL). With approximately 31 bits of internal state and a time-based seed, the private exponent is recoverable in under a minute by a passive observer. A network attacker who can observe the MS-Logon II handshake (via sniffing, recording, or man-in-the-middle) can derive the shared DH key and decrypt the encapsulated username and password, resulting in full credential disclosure. This affects legacy MS-Logon II connections; MS-Logon III (X25519 + AES-256-GCM) is unaffected.

Puntuación CVSS

Score: 7.4/10 — Severidad: HIGH — Estado NIST: Modified

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

Productos afectados

Ultravnc — Uvnc

Debilidades (CWE)

CWE-326, CWE-338

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.
← Volver a todas las alertas