Empresa
¿Quiénes somos? Visión y Valores
Herramientas
Email Checker Vigía DNS SSL Checker Password Strength HTTP Headers
Alertas
Todas las alertas Vulnerabilidades Incidentes Solo críticas En CISA KEV
Editorial
Análisis técnico ¿Cuál es mi IP?
Blog
Blog 2MCI ISO 27001 Amenazas LATAM Recursos Gratuitos eBook Gratuito Newsletter Podcast / YouTube
Empresa
Servicios Contacto Suscribirse al Newsletter
🆕 Nuevo en 2MCI
✨ Crear cuenta gratis 🛠️ Ver herramientas sin registro
Ya tengo cuenta
🔒 Iniciar sesión
Equipo
🏠 Portal interno 2MCI
Alto CVE-2026-80569 Multiple Vendors

[CVE-2026-80569] In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - bound t…

Vulnerabilidad · Publicado 26/08/2026 · Actualizado 27/08/2026

7.8
CVSS 3.x
04 Medio7 Alto9 Crítico10
Severidad: Alto
Resumen ejecutivo

In the Linux kernel, the following vulnerability has been resolved:

Input: synaptics-rmi4 - bound the F54 report size to the allocated buffer

rmi_f54_work() reads a diagnostics report from the device into
f54->report_data, sizing the transfer with rmi_f54_get_report_size():

report_size = rmi_f54_get_report_size(f54);
...
for (i = 0; i < report_size; i += F54_REPORT_DATA_SIZE) {
int size = …

Descripción técnica

Descripción técnica

In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - bound the F54 report size to the allocated buffer rmi_f54_work() reads a diagnostics report from the device into f54->report_data, sizing the transfer with rmi_f54_get_report_size(): report_size = rmi_f54_get_report_size(f54); ... for (i = 0; i < report_size; i += F54_REPORT_DATA_SIZE) { int size = min(F54_REPORT_DATA_SIZE, report_size - i); ... rmi_read_block(.., f54->report_data + i, size); } report_data is allocated once at probe from F54's own electrode counts (array3_size(f54->num_tx_electrodes, f54->num_rx_electrodes, sizeof(u16))), but rmi_f54_get_report_size() computes the size from drv_data->num_*_electrodes when those are set, i.e. from the F55 function's electrode counts. Both counts come straight from device queries (F54 and F55 each report up to 255 electrodes) and nothing constrains the F55 counts to the F54 ones. A malicious or malfunctioning RMI4 device that reports larger F55 electrode counts than its F54 counts makes report_size exceed the allocation, so the read loop writes past report_data (and the V4L2 dequeue memcpy() then reads past it). On conforming hardware the F55 configured electrodes are a subset of the F54 physical electrodes, so report_size never exceeds the buffer and well-behaved devices are unaffected. Record the allocation size and reject a report that does not fit, mirroring the existing zero-size check.

Puntuación CVSS

Score: 7.8/10 — Severidad: HIGH — Estado NIST: Received

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Fuente oficial

Publicado en NIST NVD.

¿Qué hacer?
  • Revisar el aviso oficial del fabricante y aplicar los parches o mitigaciones disponibles
  • Consultar las referencias en NIST NVD para actualizaciones de estado
  • Priorizar según el score CVSS y la exposición de los sistemas afectados
Esta alerta fue generada automáticamente a partir del NVD del NIST.
← Volver a todas las alertas